Acofar Syringe with Needle 2 ml 40/8 1 unit
search
  • Acofar Syringe with Needle 2 ml 40/8 1 unit

Acofar Syringe with Needle 2 ml 40/8 1 unit

Sterile single-use syringe, 2 ml capacity with 40 gauge needle and 8 mm length. Designed for precise administration of injectable solutions, with silicone lubrication and sterile ethylene oxide packaging.

2 ml needle.

€0.42
In Stock

  • Free samples with orders over 59€!
  • Need more units? Can't find what you're looking for? Contact us
  • ecommerce trust seal Secure paypments Payment Methods
Acofar Syringe with Needle 2 ml 40/8 1 unit
All product information

The Acofar 2 ml 40/8 syringe is a single-use medical device designed for the controlled administration of injectable solutions in authorized clinical and home settings. The barrel and stem are made of non-pyrogenic and non-toxic polypropylene, while the piston uses a synthetic polyisoprene elastomer that ensures smooth movement and a tight seal. The needle cannula is made of stainless steel and lubricated with silicone oil to minimize friction during insertion and optimize comfort during injection. The hub and cap are made of polypropylene, providing a secure fit and protecting the needle point before use.

The 40-gauge (very fine) and 8 mm long needle reduces tissue trauma and potential pain associated with the injection, making it suitable for applications requiring precision and minimal invasiveness. The syringe is supplied in a sterile, single-unit package, sterilized with ethylene oxide, ensuring the absence of microbiological contaminants upon opening. As a sterile product, it does not exert antimicrobial activity or provide protection against bacteria, viruses, or fungi; its function is to preserve the integrity of the drug until the time of administration.

The design and materials facilitate accurate measurement of small volumes (clear markings up to 2 ml), useful in medications with adjusted doses.

This is a single-use product; it is neither reusable nor refillable. Safety and proper disposal require adherence to healthcare waste regulations (sharps containers) to prevent contamination or needlestick injuries. Before use, check the integrity of the individual packaging and do not use if the packaging is damaged or open.

Automatic translation. It may contain errors.

Our Online Pharmacy offers free shipping to all of Spain and the Andalusian community, including Almería, Cádiz, Córdoba, Granada, Huelva, Jaén, Málaga and Seville.

Dosage accuracy: allows administration of exact volumes up to 2 ml.
Low pain perception: very fine (40 gauge) and short (8 mm) needle that minimizes trauma to the skin.
Controlled sliding: poly-isoprene piston and silicone oil lubrication facilitate smooth injection.
Microbiological safety at the start: sterile single-unit packaging, sterilized with ethylene oxide.
Single-use and non-reusable: reduces the risk of cross-contamination and transmission of pathogens if disposed of properly.
Compatibility with liquid drugs: inert materials (polypropylene and stainless steel) suitable for injectable solutions.

Does this syringe eliminate bacteria, viruses, or fungi?
No. The syringe is supplied sterile after sterilization with ethylene oxide, but the device has no antimicrobial activity or continuous protection against microorganisms.

Is it reusable or rechargeable?
No. It is a single-use product designed to be discarded after a single administration to avoid risks of contamination and accidents.

For which routes of administration is the 40/8 needle suitable?
The combination of 40 gauge and 8 mm length is indicated for applications requiring a very fine and short needle, such as certain subcutaneous injections. The selection of route and technique depends on the medication prescription and current clinical guidelines.

How is sterility guaranteed?
Sterility is achieved through treatment with ethylene oxide and the product is presented in a unit package that protects asepsis until it is opened.

What to do with the syringe after use?
It must be disposed of in sharps containers according to applicable local regulations; it must not be disposed of in ordinary household waste.

Is it compatible with any injectable medication?
The materials (polypropylene and stainless steel) are compatible with most injectable solutions. It is advisable to verify specific compatibility in the drug's data sheet and with the supplier.

1. Preliminary check: verify that the unit packaging is intact and without signs of tampering.
2. Assembly: Adjust the needle to the syringe cone by pressing with a slight twist until it fits securely.
3. Remove the protective needle cap by gently pulling the cap straight out.
4. Aspiration: extract the prescribed dose from the vial or ampoule, respecting the graduation marks up to 2 ml.
5. Bubble removal: Gently move the piston to expel air and adjust the final dose in the syringe.
6. Administration: perform the injection technique according to the route and procedure indicated in the prescription and corresponding clinical regulations.
7. Post-use: Place the protective cap if local regulations allow, or dispose of the used syringe directly in a sharps container; do not reuse.

Check the integrity of the individual packaging before use; do not use if the package is damaged.
Do not reuse under any circumstances; reuse increases the risk of transmission of infections.
Dispose of in approved sharps containers according to local and health regulations; follow healthcare waste management guidelines.
Avoid handling the needle without protection to minimize the risk of accidental needle stick; handling by trained personnel only.
It is not a product with antimicrobial activity nor does it provide long-lasting protection against microorganisms.
Check the compatibility of the materials with the drug to be administered according to the drug's technical data sheet.
Keep in its packaging until ready for use and store at room temperature, away from sources of extreme heat and humidity.

2 ml. 40 gauge needle, 8 mm length. Sterile single-unit packaging. 1 unit per package.

Syringe: cylinder and stem in pyrogen-free and non-toxic polypropylene; piston in synthetic poly-isoprene elastomer.
Needle: stainless steel cannula lubricated with silicone oil; cone and cap in polypropylene.