It allows pregnancy to be detected up to 6 days before the missed period.
Over 99% accurate from the expected day of your period and easy-to-read results.
Packaging 2 units.
The ultra-early analog test detects the human chorionic gonadotropin (hCG) hormone using a test strip immobilized in a plastic casing.
The immunological reaction between specific antibodies and the hormone present in the urine produces visible lines in the result window that allow the identification of pregnancy or non-pregnancy.
The device's sensitivity allows for reading up to 6 days before the expected date of the menstrual cycle, with an accuracy of over 99% from the expected day of menstruation.
The analog format offers a direct interpretation through the appearance of lines: a control line to validate the test and a result line to indicate detectable hCG.
The construction incorporates an absorbent tip designed for rapid sample collection and a clear reading window that reduces ambiguity in interpretation.
The product is intended for in vitro diagnostic use and meets the CE marking requirements for home use diagnostic devices.
Storage stability allows the product to be stored between 2°C and 30°C, maintaining functionality until the expiration date indicated on the packaging.
Presenting two units facilitates subsequent confirmations or repetitions in case of ambiguous results.
For reliable interpretation, it is recommended to use the first urine of the morning for higher concentrations of hCG; however, the test maintains adequate sensitivity in samples collected throughout the day if early detection is required.
Common causes of false negative or positive results include recent use of hCG medications, testing performed outside the detection window, or reading outside the recommended time.
In case of any doubt or conflicting results, confirmation through blood tests or consultation with a healthcare professional is suggested.
Automatic translation. It may contain errors.
Farmaten offers free shipping to the entire country, including large cities such as Madrid or the cities of Castilla León, Ávila, Burgos, León, Palencia, Salamanca, Segovia, Soria, Valladolid and Zamora.
- Early detection up to 6 days before missed period.
- Accuracy greater than 99% from the expected day of menstruation.
- Results legible in 3 minutes using visible lines (control and result).
- Presentation of 2 units for verification or repetition.
- Absorbent tip design and reading window that facilitate interpretation.
- CE marked product intended for in vitro diagnostics.
- Compatible with the parapharmacy range: oral hygiene, intimate hygiene, deodorants and bath gels.
When can the test be performed to obtain the most reliable result?
Maximum reliability is achieved from the day menstruation is expected; the test allows detection up to 6 days before, although the probability of obtaining a positive result increases as the expected date approaches.
What do the lines in the results window mean?
A line in the control zone confirms that the test has worked; the additional appearance of the result line indicates the presence of hCG and therefore a possible pregnancy.
How accurate is the test?
The test offers over 99% accuracy when used from the day menstruation is expected. Sensitivity before that date is high but decreases the earlier the test is taken.
Is it possible to get a false positive or a false negative?
Yes. False positives can be caused by medications containing hCG or by rare medical conditions; false negatives can result from insufficient hCG concentration in the sample, testing performed too early, or improper handling.
How long do we have to wait to read the result?
The result should be read after 3 minutes. Readings taken outside the recommended time may not be valid.
Can the test be reused?
No. It is a single-use device for in vitro diagnostics.
How should the test be stored?
Store between 2°C and 30°C, protected from prolonged humidity and direct light. Do not use after the expiry date shown.
What to do if the control line does not appear?
The absence of the control line indicates an invalid result; it is recommended to repeat the test with a new unit or confirm by laboratory analysis.
-The protective cap is removed and the absorbent tip is exposed.
-The absorbent tip is placed under a stream of urine for 5 seconds or immersed in a urine sample collected in a clean container for 20 seconds.
-Next, the device is placed on a flat surface with the window facing upwards.
-After 3 minutes, the window is observed to determine the presence or absence of the result line along with the control line.
-Do not interpret results more than 10 minutes after they have been taken.
- Exclusive use for in vitro diagnosis.
- Not reusable.
- Keep out of reach of children.
- Store between 2°C and 30°C; avoid freezing and prolonged exposure to sunlight.
- Read the enclosed instruction leaflet before use for details on interpretation.
- Atypical results or contradictions with clinical symptoms require confirmation through blood tests or medical consultation.
- Medications containing hCG or specific medical conditions may alter the result.
- Avoid reading before 3 minutes or after 10 minutes, as this may lead to incorrect interpretations.
-Pack with 2 units.
-hCG sensitive test strip, plastic casing with reading window, absorbent tip and packaging materials.
-CE marking and labelling in accordance with regulations for in vitro diagnostic devices.